xutil.dev
Login

PCB Trace Width Calculator

Calculate required PCB trace width based on IPC-2221 standard for current carrying capacity

Common Current Values
0.3 A (Signal)0.5 A (Low power)1 A (Medium power)2 A (Power)3 A (High power)5 A (Heavy power)10 A (Very heavy)
Input Parameters

= 35 µm = 1.38 mils

Based on IPC-2221 standard

A = (I / (k × ΔT^0.44))^(1/0.725)

k = 0.048 (External), 0.024 (Internal)

Results

External Layer

0.300 mm

11.8 mils

Cross-section: 16.3 mils²

Resistance: 0.0820 Ω

Voltage Drop: 81.99 mV

Power Loss: 81.99 mW

Internal Layer

0.781 mm

30.8 mils

Cross-section: 42.4 mils²

Resistance: 0.0315 Ω

Voltage Drop: 31.52 mV

Power Loss: 31.52 mW

External Trace Width Reference (1 oz, 10°C rise)

CurrentWidth (mm)Width (mils)
0.5 A0.115 mm4.5 mils
1 A0.300 mm11.8 mils
2 A0.781 mm30.8 mils
3 A1.367 mm53.8 mils
5 A2.765 mm108.9 mils
7 A4.399 mm173.2 mils
10 A7.194 mm283.2 mils