xutil.dev
Login

Floor Load Calculator

Reference table of live loads by occupancy type — residential, office, warehouse, retail — per building codes — free design tool

Search
Live Loads by Occupancy (Japanese Building Code)
CategoryDescriptionFloor Load (N/m²)Seismic Load (N/m²)Floor (kN/m²)
ResidentialDwelling rooms in houses and apartments1,8006001.8
OfficeGeneral office spaces2,9008002.9
RetailDepartment stores and retail floors2,9008002.9
ClassroomSchool classrooms2,3001,1002.3
WarehouseGeneral warehouses3,9002,4003.9
ParkingGarages and parking areas5,4002,0005.4
HospitalHospital rooms and clinics2,9008002.9
AssemblyAssembly halls, theaters, cinemas3,5001,6003.5
Rooftop PlazaRooftop plazas (non-heliport)2,9008002.9
Corridors/StairsCommon corridors and staircases2,9008002.9
BalconyResidential balconies1,8006001.8
Library/ArchiveLibraries and archive rooms7,8003,0007.8
Notes
  • Based on Building Standards Act Enforcement Order Article 85
  • Floor Load: Used for structural calculation of slabs and secondary beams
  • Seismic Load: Live load used for seismic force calculation
  • In actual design, also check local authority guidelines