xutil.dev
Login

Gutter Flow Calculator

Calculate gutter flow capacity using Manning equation for U-shaped and L-shaped gutters — free hydraulic calculation tool

Standard Gutter Sizes
Gutter Parameters

Concrete: 0.013, PVC: 0.010

Cross Section
300mm300mm
Calculation Results
Flow Area A
0.0900
Hydraulic Radius R
0.1000
m
Velocity V
2.344
m/s
Flow Rate Q
0.2109
m³/s
(210.9 L/s)
Manning's Equation:
V = (1/n) · R^(2/3) · i^(1/2)
V = (1/0.013) · 0.1000^(2/3) · 0.0200^(1/2)
V = 2.344 m/s
Q = A · V = 0.0900 × 2.344 = 0.2109 m³/s