xutil.dev
Login

Daylighting Calculator

Calculate daylight correction factor and effective daylighting area per building code — free architectural design tool

Related Categories:Building Services
Room Type
Required ratio: Effective window area / Floor area ≥ 1/7 (14.3%)
Area Input
Window Position
Obstruction Angle: 42.0°
Daylighting Check Result
FAIL
9.00% < 14.29%
Calculation Details
Window Area3.6
Correction Coefficient0.50
Effective Window Area1.80
Floor Area20
Effective / Floor9.00%
Required Ratio1/7 = 14.29%
Required Window Area5.71
Formula

Effective Area = Window x Coeff

= 3.6 x 0.50 = 1.80

Check: 1.80 / 20 = 9.00%

< 14.29% (1/7)

Correction Coefficients (Side Window)
Obstruction AngleCoefficient
0° (no obstruction)1.0
< 30°0.7
30° - 45°0.5
45° - 60°0.3
> 60°0.2
Top light3.0
Required Ratios by Room Type
TypeRequired Ratio
Residential1/7 (14.3%)
School1/5 (20.0%)
Hospital1/7 (14.3%)
Nursery1/5 (20.0%)
Office1/10 (10.0%)