xutil.dev
Login

Condensation Checker

Check interstitial condensation risk with dew point and temperature gradient visualization — free building physics tool

Related Categories:Building Services
Temperature & Humidity

Indoor

Outdoor

Indoor Dew Point: 12.0°C
Material Presets
Wall Layers (from interior)
Layer 1
Layer 2
Layer 3
Condensation Check
CONDENSATION RISK
Location(s): After Glass Wool 16K, After Concrete
Temperature Profile vs Dew Point
PositionTemp (°C)Dew Pt (°C)Status
Indoor Surface19.112.0OK
After Plasterboard18.712.0OK
After Glass Wool 16K1.112.0RISK
After Concrete0.312.0RISK
Temperature Distribution
Indoor Surface
19.1°CDP: 12.0°C
After Plasterboard
18.7°CDP: 12.0°C
After Glass Wool 16K
1.1°CDP: 12.0°C
After Concrete
0.3°CDP: 12.0°C
Temp (safe)
Temp (risk)
Dew point
Dew Point Formula

Magnus Formula:

alpha = (17.27 x T) / (237.3 + T) + ln(RH / 100)

Td = (237.3 x alpha) / (17.27 - alpha)

Indoor: T=20°C, RH=60%

Td = 12.00°C